Intoxalock LED Messages User Manual - Manuals+ (2023)

Intoxalock LED Messages User Manual - Manuals+ (1)

Contents hide

1Intoxalock LED Messages

2Start up messages

3Warm up messages

4Action messages

5Breath sample messages

6BREATH SAMPLE MESSAGES CONTINUED

7Loss of power messages

8LOSS OF POWER MESSAGES CONTINUED

9Service messages

10Related Posts

Intoxalock LED Messages

Intoxalock LED Messages User Manual - Manuals+ (2)

Start up messages

Displayed when the activation button is pushed.

Low Car Voltage
Message displayed when your car battery voltage is low. Charge your battery following the instructions in your user’s manual.

Wait for unit to reset
A breath sample was submitted within the past 3 minutes and the device is resetting.

Clearing
The device is preparing for a breath sample clearing any previous alcohol content from the fuel cell.

Blow
The device is ready for you to start blowing.

Blowing
Displayed as you are submitting your breath sample.

Sampling
Displayed when the device is analyzing the breath sample you submitted.

Key is On
The key is in the “On” position and the device has not received a breath sample. Turn the key off and submit a breath sample after the reset countdown has expired.

Car Start
The device is acknowledging that you have started your vehicle.

Warm up messages

Displayed when the device is warming up. You may see a combination of these messages.

Wait for unit to warm up
In cold weather, the device may need to use the internal heater to “warm up” before submitting a breath test.

  • 5 seconds of full on
  • 1 second of WARMING
  • ½ second of PRESS
  • ½ second of TO

These messages are displayed as part of the warm-up process. You may press the activation button to submit a breath sample if any of these are displaying.

Action messages

Displayed when you need to take action.

Waiting for restart
The device has registered your vehicle has been shut off. You may restart your vehicle during this countdown without submitting a breath sample.

Rolling Retest, Roll Test or Rolling Test
The device is requesting you submit an additional breath sample after the vehicle has been started as mandated by your state.

Approaching TimeOut
A breath sample has not been provided in within the time allotted by your state. You need to submit a breath sample immediately or the device could record the missed test as a refusal and enter into a Lock-Out.

Breath sample messages

Displayed when the breath sample cannot be accepted.

PASSED or PASS
The breath sample submitted was below the state set BrAC level and you may start your vehicle.

FAILED or FAIL
The breath sample submitted was at or above the state set BrAC level and the vehicle will not start.

GREEN
The breath sample submitted had a BrAC of 0.00 and you may start your vehicle.

YELLOW
The breath sample submitted had a BrAC reading, but the level is below the preset state limit. Use caution driving after submitting a “YELLOW” BrAC as alcohol levels can fluctuate.

RED
The breath sample submitted had a BrAC at or over the preset state limit and the vehicle will not start.

NOT ENOUGH SUCTION
You did not inhale back through the device long enough when submitting your breath sample. With your next breath sample, count at least 2 beeps while inhaling.

EARLY SUCTION DETECTED
You started inhaling back through the device too soon. With your next breath sample, wait to hear at least 3 beeps while blowing before starting to inhale.

LATE SUCTION DETECTED
You waited too long before inhaling back through the device during your breath sample. With your next breath sample, start inhaling after blowing for 2- 4 beeps.

NOT ENOUGH HUMMING
You did not hum long enough while submitting your breath sample. With your next breath sample, hum for at least 3 beeps.

EARLY HUMMING DETECTED
You started humming too soon while submitting your breath sample. With your next breath sample, count at least 3 beeps while blowing before you start humming.
This message may or may not appear depending on the regulations of your state

BREATH SAMPLE MESSAGES CONTINUED

LATE HUMMING DETECTED
You waited too long to start humming during your breath sample. With your next sample, start humming after blowing for 2-4 beeps.

TOO MUCH PRESSURE
You are blowing too hard while trying to submit your sample.

INVALID SAMPLE PRESSURE
You have not supplied enough breath pressure to activate the breath sensor or you have not maintained enough pressure during the sampleto complete the test.

VOLUME TOO HIGH
You are blowing too much air into the device.

TOO SOFT
You are not blowing hard enough to activate your device.

DID NOT BLOW IN TIME
You did not start blowing soon enough after you pressed the device displayed BLOW on the LED. Press the activation button and start blowing when the LED displays BLOW.

NOT ENOUGH BREATH CHANGE DETECTED
Your breath pattern did not change with enough suction or humming for the device to notice. Inhale deeper or hum louder on your next attempt.

EARLY BREATH CHANGE DETECTED
You began submitting your sample either by inhaling or humming. You must blow 2-4 seconds before changing the blow pattern.

LATE BREATH CHANGE DETECTED
You have attempted to submit a breath sample in a manner the device is not set for. If you changed the blowing technique and received this message, try simply blowing for 5-6 seconds without changing the pattern.

STOP BLOWING
You started to blow before the device was ready. With your next breath sample, wait until the LED displays BLOW.

INVALID BREATH SAMPLE
The temperature of the breath sample is out of the acceptable range. See Warm/Cold weather tips in your User’s Manual.

BLOW AGAIN
Your breath sample was not accepted. Submit another breath sample.

PUMP FAILURE
The internal pump has failed and a sample cannot be accepted. Contact Intoxalock immediately.

Loss of power messages

Displayed when the device regains power.

CAR BATT
Your car battery’s voltage is less than 10V. Please charge your battery

WV4.24
This is the current version of firmware running on your handheld. This will only show if your battery’s voltage is greater than 10V.

LOSS OF POWER MESSAGES CONTINUED

The device has been disconnected
Your device had lost power longer than the time allotted by your state. Your device may enter into a Lock-Out. If it does, please contact Intoxalock as soon as possible.

Service messages

Displayed when the button is pushed or the device enters idle.

RECALL – Service required in 3 days 4 hrs 5 mins
Your device will display the number of days, hours, and minutes before it will expire. Check your User’s Manual for the next steps to receive your calibration

Driving not allowed at this time
This message will appear if you have been restricted to driving only during certain times of the day. You will be able to start your vehicle normally with a passing breath sample during your approved times.

LOCKOUT in effect – 4 mins
A temporary Lock Out can range from 5 minutes to 24 hours during which you will not be able to start your car. Once the countdown has expired, you will be able to start your vehicle as usual with a passing breath sample.

LOCKOUT in effect – Service required in 2 days 3 hrs 4 mins
If your device enters into service Lock Out, the device will display the time remaining before you will no longer be able to start your vehicle. You will need to contact Intoxalock immediately if this message appears on your device.

LOCKOUT – Service required immediately
Your current device will expire shortly. Contact Intoxalock to request a new device immediately if you have not already done so. The unit was not serviced in time Your current device was not serviced in time. You will need to contact Intoxalock to schedule the delivery of a newly calibrated device.

COURT 14 LOCKOUT
If you are being monitored by Court 14 in Harris County, TX and your device enters into a Lock-Out, you will not be allowed to start your vehicle until the court releases you. You must contact Court 14 immediately.

LOG FULL – Service required in 3 days 4 hrs 5 mins
This message will be displayed if the device’s memory capacity is filling up due to excessive use and needs to be serviced early. Contact Intoxalock to schedule the delivery of a new device. This message is rarely displayed.

Warning RUN WIRE
If this message appears on your LED screen, contact Intoxalock immediately. You will need to return to the service center for an inspection. This message may or may not appear depending on your state’s regulations

  • 10520 Hickman Road, Des Moines, IA 50325
  • (877) 777-5020
  • Fax: (515) 331-7513
  • www.Intoxalock.com

View Fullscreen

Related Posts

  • ASUS LED Projecktor User Manual

    LED Projecktor

  • LIDEKA LED strip User Manual

    LED strip

  • LG LED TV User Manual

    LG LED TV User Manual - Optimized PDF LG LED TV User Manual - Original PDF

  • Insignia LED TV User Manual

    Insignia LED TV User Manual - Optimized PDF Insignia LED TV User Manual - Original PDF

Top Articles
Latest Posts
Article information

Author: Clemencia Bogisich Ret

Last Updated: 10/27/2022

Views: 5665

Rating: 5 / 5 (60 voted)

Reviews: 91% of readers found this page helpful

Author information

Name: Clemencia Bogisich Ret

Birthday: 2001-07-17

Address: Suite 794 53887 Geri Spring, West Cristentown, KY 54855

Phone: +5934435460663

Job: Central Hospitality Director

Hobby: Yoga, Electronics, Rafting, Lockpicking, Inline skating, Puzzles, scrapbook

Introduction: My name is Clemencia Bogisich Ret, I am a super, outstanding, graceful, friendly, vast, comfortable, agreeable person who loves writing and wants to share my knowledge and understanding with you.